Print

DF02001

TUNDRA II WOOD FURNACE

Heating area 1,000 - 2,500 Ft2
Size 33 1/4" W X 49 1/8" D X 63 1/2" H
Maximum log length 21"
Average particulate emissions rate (1) (2) 0.654 lb/mmBTU (0.282 g/MJ)

From USD $2,199.00

  • Description
  • Options and Accessories
  • Specs / Manual
  • Support and parts
  • Reviews (17)

Description

Drolet is proud to present the Tundra II, a completely re-engineered high efficiency wood furnace that meets the new EPA (CSA B415.1-10) clean-air standards. This enhanced furnace will provide considerable energy savings over a conventional wood furnace, using up to 30% less wood for the same amount of heat.

The Tundra II is equipped with an adjustable rectangular hot air plenum that can accommodate 6 to 10, 6-inch diameter heating ducts. This adjustable plenum provides greater flexibility for an easier installation. Another key feature is an electronic probe, which measures the temperature in the plenum and varies the blower speed accordingly, assuring maximum comfort.

The Drolet Tundra II: Sophisticated comfort control!

Discover the additional qualities of the Drolet Tundra II wood furnace

100% of the last 6 homeowners who have registered their warranty are satisfied with this product.

Options and Accessories

Options

Picture
Part number and description
Price
Shipping time

CARDBOARD FRAME AIR FILTER WITH SUPPORT (20' X 15' X 1')

AC01390
CARDBOARD FRAME AIR FILTER WITH SUPPORT (20" X 15" X 1")

From USD $39.00 MSRP

In stock

COLD AIR RETURN HOUSING WITH FILTER

AC01392
COLD AIR RETURN HOUSING WITH FILTER

From USD $69.00 MSRP

In stock

DIGITAL WALL THERMOSTAT

AC05558
DIGITAL WALL THERMOSTAT

Fits on most thermostatically controlled pellet or gas appliances and furnaces. Temperature displayed in °C/°F. Includes 30 feet of millivolt wire.

From USD $59.00 MSRP

In stock

TRIPLE HOT AIR SUPPLY ADAPTER KIT

AC01396
TRIPLE HOT AIR SUPPLY ADAPTER KIT

From USD $49.00 MSRP

In stock

WASHABLE ALUMINUM AIR FILTER  WITH SUPPORT (20' X 15' X 1')

AC01391
WASHABLE ALUMINUM AIR FILTER WITH SUPPORT (20" X 15" X 1")

From USD $69.00 MSRP

In stock

Accessories

Adhesives, gaskets and insulation

Picture
Part number and description
Shipping time

HIGH TEMPERATURE RED SILICONE (300 mL- 10.1 FL.OZ.)

AC02040
HIGH TEMPERATURE RED SILICONE (300 mL- 10.1 FL.OZ.)

A premium quality 100% silicone sealant that stays permanently flexible. Suitable for sealing around oven windows, flues on gas appliances, joints and metal stacks and ductwork. An excellent gasket maker to replace existing cork and felt rubber. Ideal for holding gaskets around stove and fireplace doors. Oxygen sensor safe. Withstands continuous temperatures up to 260°C or 500°F.

USD $7.00
In stock

HIGH TEMPERATURE CLEAR SILICONE (300 mL - 10.1 FL.OZ.)

AC02045
HIGH TEMPERATURE CLEAR SILICONE (300 mL - 10.1 FL.OZ.)

A premium quality 100% silicone sealant that stays permanently flexible. Suitable for sealing around oven windows, flues on gas appliances, joints and metal stacks and ductwork. An excellent gasket maker to replace existing cork and felt rubber. Ideal for holding gaskets around stove and fireplace doors. Oxygen sensor safe. Withstands continuous temperatures up to 204°C or 400°F.

USD $6.00
In stock

HIGH TEMPERATURE RED SILICONE (83 mL - 2.8 FL.OZ.)

AC07850
HIGH TEMPERATURE RED SILICONE (83 mL - 2.8 FL.OZ.)

Premium quality 100% silicone adhesive.
Withstands continuous temperature up to 343 °C (650 °F).

USD $5.00
In stock

Paint

Picture
Part number and description
Shipping time

METALLIC BLACK STOVE PAINT - 342 g (12oz) AEROSOL

AC05959
METALLIC BLACK STOVE PAINT - 342 g (12oz) AEROSOL

High temperature paint with quick drying, lead free. Excellent adherence and color retention.

USD $12.00
In stock

METALLIC BLACK STOVE PAINT - 85 g (3oz) AEROSOL

AC05963
METALLIC BLACK STOVE PAINT - 85 g (3oz) AEROSOL
Fits most products with a metallic black finish.
USD $7.00
In stock

Maintenance products

Picture
Part number and description
Shipping time

STOVE AND FURNACE CEMENT (300 mL - 10.1 FL.OZ.)

AC02540
STOVE AND FURNACE CEMENT (300 mL - 10.1 FL.OZ.)

Dries to seal cracks and joints to prevent smoke or air leaks. SBI Stove & Furnace Cement may be used in stoves, furnaces, boilers, fireplaces (all fuels), combustion chambers, firedoors, flue and chimney joints, brick linings, gasketing.

USD $5.00
In stock

ASH VACUUM CLEANER

AC02582
ASH VACUUM CLEANER

Conforms to UL STD. 1017. Certified to CSA STD. C22.2 No. 243-10. Avoid ending prematurely the life of your vacuum cleaner by using the ideal tool to suck up the completely cooled ashes of your wood or pellet appliance. Designed almost exclusively for ash collection, this ash vacuum cleaner will offer several years of service with proper care. Power: 800 W.

Download the owner's manual  >

USD $99.00
In stock

6" ROUND BRUSH WITH POLYPROPYLENE BRISTLES (3/8" NPT)

AC04500
6" ROUND BRUSH WITH POLYPROPYLENE BRISTLES (3/8" NPT)

Ideal to prevent creosote build-up inside the chimney.

USD $10.50
In stock

KEVLAR THREAD WOOD STOVE AND FIREPLACE GLOVES

AC07820
KEVLAR THREAD WOOD STOVE AND FIREPLACE GLOVES

Recommended for a clean and safe use of any type of wood-burning appliance. Fire-resistant kevlar sewings.

USD $19.00
In stock

19" KEVLAR THREAD SEWN FIREPLACE GLOVES

AC07822
19" KEVLAR THREAD SEWN FIREPLACE GLOVES

Thermal protective gloves with long cuffs (19" or 48 cm):

  • Ideal for stove, fireplace and barbecue
  • Highly resistant to high temperatures
  • Genuine leather and kevlar seams for increased durability
  • Maximum protection against all heat sources (covers the entire forearm)
  • Strong and flexible glove with reinforcement at the level of the hand
  • One-sized with cotton lining for comfort
  • Practical leather support buckle
USD $27.00
In stock

DRY CLEANING PAD

AC07824
DRY CLEANING PAD

Easily cleans the soot from glass without water.

USD $11.00
In stock

WOOD APPLIANCE GLASS CLEANER (500 mL - 16.9 FL.OZ.)

AC07825
WOOD APPLIANCE GLASS CLEANER (500 mL - 16.9 FL.OZ.)

Recommended for cleaning the glass of any type of wood-burning appliance.

USD $6.00
In stock

Meters

Picture
Part number and description
Shipping time

MAGNETIC THERMOMETER

AC07830
MAGNETIC THERMOMETER

Recommended for all wood stoves installed with a single wall stove pipe.

Download the owner's manual  >

USD $9.50
In stock

DIGITAL MOISTURE READER

AC07835
DIGITAL MOISTURE READER

Accurately and professionally measures moisture in wood logs.

Download the owner's manual  >

USD $49.00
In stock

PROBE THERMOMETER

AC07840
PROBE THERMOMETER

Recommended for all wood appliances installed with a double wall stove pipe.

Download the owner's manual  >

USD $14.00
In stock

Fire starters

Picture
Part number and description
Shipping time

FIRE LIGHTING GEL (1 L - 32 FL.OZ.)

AC02550
FIRE LIGHTING GEL (1 L - 32 FL.OZ.)

Recommended for lighting-up oil, wood, and pellet stoves. Leaves no residue. Odorless. 

USD $8.00
In stock

SACHET POUCHES FIRE STARTER

AC02597
SACHET POUCHES FIRE STARTER

Paraffin sachet pouches. Odorless.

USD $7.50
In stock

ONE-STRIKE FIRE STARTER

AC02598
ONE-STRIKE FIRE STARTER

Specially treated fibrous wood prepared with paraffin wax, pre-cut into sticks with ignition head on the bottom of the sticks and striking surface on package.

USD $7.00
In stock

WOOD AND PARAFFIN FIRE STARTER CUBES

AC02599
WOOD AND PARAFFIN FIRE STARTER CUBES

• Only made from wood and paraffin wax without additional
   chemicals (like formaldehyde)
• Safe, odorless, soot less, strong burning
• Easy to handle and easy to use
• Can be stored indefinitely and does not dry out
• Burn for 12 minutes

 

USD $7.50
In stock

FIRE LIGHTING GEL (500 mL - 16 FL.OZ.)

AC04099
FIRE LIGHTING GEL (500 mL - 16 FL.OZ.)

Recommended for lighting-up oil, wood and pellet stoves.  Leaves no residue.  Odorless.

USD $5.50
In stock

Hearth pads

Picture
Part number and description
Shipping time

MODULAR HEARTH PAD PROTECTION SYSTEM

AC02705
MODULAR HEARTH PAD PROTECTION SYSTEM

Ideal for floor protection for stoves and fireplaces.  Use as a protective and insulating layer under ceramic tile or other non-combustible materials.  Handles more easily than gypsum panels.               

Download the owner's manual  >

USD $319.00
Contact dealer

Specs / Manual

Appliance performance (3)

Fuel type Dry cordwood
Recommended heating area (sq.ft.) () 1,000 - 2,500
Firebox nominal volume (cu. ft.) 3.6
Maximum burn time () 10 h
Maximum input capacity (dry cordwood) (4) 310,000 BTU
Overall heat output rate (min. to max.) (5) 15,436 BTU/h (4.5 kW) to 49,638 BTU/h (14.5 kW)
Average overall efficiency (min. to max.) (6) 76.7 % (HHV) (7) 82.9 % (LHV) (8)
Delivered heat output rate (min. to max.) (9) 12,635 BTU/h (3.7 kW) to 44,857 BTU/h (13.1 kW)
Average delivered efficiency (min. to max.) (10) 62.7 % (HHV) (7) 68.3 % (LHV) (8)
Optimum efficiency (11) 85 %
Average particulate emissions rate (1) (2) 0.654 lb/mmBTU (0.282 g/MJ)
Average CO (12) 11.22 lb/mmBTU (4.81 g/MJ)
Average electrical power consumption (13) 250 Wh

(1) Based on delivered heat output.

(2) This appliance is officially tested and certified by an independent agency.

(3) Values are as measured per CSA B415.1-10, except for the recommended heating area, firebox volume, maximum burn time and maximum input capacity. Performances based on a fuel load prescribed by the standard at 10 lb/ft³ and with a moisture content between 18% and 28%.

(4) Input value at 10 lb/ft³ fuel loading density and dry energy value of 8,600 BTU/lb.

(5) Overall : Radiated and delivered heat together at 10 lb/ft³ fuel loading density over one total burn cycle.

(6) Efficiency based on radiated and delivered heat when allowing cycling from high to low burn to simulate thermostat demand.

(7) Higher Heating Value of the fuel.

(8) Lower Heating Value of the fuel.

(9) Delivered: Remotely provided to other rooms through ducting at 10 lb/ft³ fuel loading density over one total burn cycle.

(10) Efficiency based on delivered heat when allowing cycling from high to low burn to simulate thermostat demand.

(11) Optimum overall efficiency at a specific burn rate (LHV).

(12) Carbon Monoxyde. Based on overall heat output at 10 lb/ft³ fuel loading density.

(13) Unless stated otherwise, measures were taken directly at the main power source and include all electrical components present in the appliance.

General features

High-efficiency EPA certified appliance Yes
Maximum log length 21"
Log positioning Over depth
Chimney diameter 6"
Flue outlet diameter 6"
Type of chimney CAN/ULC S629, UL 103 HT (2100 °F)
Baffle type C-Cast
Approved for an alcove installation No
Approved for a mobile home installation No
Shipping Weight 652 lb (296 kg)
Door type Single, glass with cast iron frame
Glass type Ceramic glass
Glass surface – dimensions (Width X Height) 14 3/8" X 10"
Glass air-wash system Yes
Blower (hp / speed / CFM) 1/4 / 4 / 1,400
Filter – dimensions (Width X Height X Depth) 15" X 20" X 1"
Overall dimension (Height) 63 1/2"
Overall dimension (Width) 33 1/4"
Overall dimension (Depth) 49 1/8"
Door opening – dimension (Height) 10"
Door opening - dimension (Width) 13 3/4"
Firebox – dimension (Height) 16 1/8"
Firebox – dimension (Width) 17"
Firebox – dimension (Depth) 22 5/8"
Firebox lined with refractory bricks for better heat distribution Yes
Stainless-steel secondary-air system improving gas combustion Yes
Adjustable threaded legs Yes
Steel thickness – body 3/16"
Steel thickness – top 1/4"
Easy-to-access ash drawer Yes
Air return plenum – dimension (Depth or Height) 22"
Air return plenum – dimension (Width) 14 1/2"
Hot air plenum – dimension (Depth or Height) 18 1/2" - 26 1/2"
Hot air plenum – dimension (Width) 22 1/4"
USA standard (emissions) EPA
Canadian Standard (emissions) CSA B415.1-10
USA standard (safety) UL 391
Canadian standard (safety) CAN/CSA B366.1
Tested and listed as per applicable standards By an accredited laboratory (CAN/USA)
Warranty Limited lifetime
Minimum clearances to combustibles*
(Data expressed in inches. 1 inch = 25.4 mm)
  Canada United-States
  Single wall pipe Double wall pipe Single wall pipe Double wall pipe
Clearance – back wall 16" 16" 16" 16"
Clearance – ducts 1" (plenum = 5") 1" (plenum = 5")
Clearance – top (measured from the platform on which the appliance is installed)** 69" 69" 69" 69"
Clearance – recommended for maintenance on option side 30" 30"
Clearance – front 48" 48"
Clearance – side wall 11" 11"
Clearance – opposite side wall 24" 24"

* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and/or web sites).

** Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.

Support and parts

Need a replacement part for your appliance?

We have everything you need! Buy it online or from your local dealer.

Find a replacement part for this product

NEED HELP ?
CONTACT-US !

1-418-908-8002
Monday to Friday
8h to 12h - 13h to 17h
(EST)

Maintenance instructions

Why does the glass get sooty?

Possible causes and solutions:

1- The moisture content of your wood is too high.

Solution: Make sure you use good, seasoned cord wood. The wood you burn plays an important role in the overall performance of your heater. Your wood should have been properly dried for approximately one year. Storage is also key. Wood that has been cut for one, two or even more years, will not necessarily be dry if it has been stored in poor conditions. Under extreme conditions, it may have rotten instead of drying. Smaller pieces of wood will dry faster. The wood should be stored in a place where the grass is not too long, and where the wind will be able to circulate between the logs. A 12-inch gap should be kept between the cords. The wood should be placed in the sunniest area and should be protected from the rain and snow on top, but not on the sides. Use a moisture reader to measure the moisture content of your wood. Ideally, it should be below 25%.

2- The logs are positioned too close to the glass and are obstructing the air flow that is necessary to keep the glass clean.

Solution: Make sure to keep a minimum gap of 2 inches between the logs and the glass.

3- The chimney draft is too weak.

Solution #1: In many cases, a weak draft is simply due to insufficient heat in the exhaust system. Build a small, intense fire, and leave the door ajar (never leave the heater unattended). Before inserting larger logs, use dry kindling to obtain a good bed of red embers. Gradually increase the size of the logs. Close the unit’s door when you reach a flue temperature of approximately 475 °F on the chimney thermometer. Leave the air intake fully open for approximately 15 minutes. Then, gradually close the air intake control. Note that there is no danger in letting the temperature inside the flue reach approximately 700 °F during the start-up. This is even favorable in order to properly start your heater. You must, however, avoid maintaining excessive temperatures (above the comfort zone on your thermometer) during a long period of time. Your chimney thermometer should be positioned on the exhaust pipe, approximately 18 inches above the unit.

Solution #2: Your heater may not have all the oxygen it needs to allow for a sufficient draft. You first need to insure that the room where the heater is located is sufficiently large and well ventilated. Open the nearest window by approximately 2 inches. If you notice a significant improvement, it is a sign that the unit needs more oxygen. The room may be too insulated or too small. Without an additional source of oxygen, the draft will remain weak and cause the glass stay dirty.

Solution #3: The chimney may be too short. In order to obtain a sufficient draft, your chimney must have a minimum height. Twelve feet (from the heater to the chimney cap outside the house) is a minimum. A height of 15 feet or higher is ideal.

Solution #4: Your exhaust system may be too tortuous or may lack a sufficiently steep slope. Ideally, your exhaust system should not have more than one 90° elbow. Furthermore, all horizontal sections should be as short as possible and have a minimum slope of ¼" per foot.

Solution #5: Your exhaust system may be oversized. When your chimney is oversized, the volume of air that needs to be warmed-up is larger. It is therefore difficult to reach temperatures that will allow for a sufficient draft. Most advanced combustion systems (those certified to EPA/CSAB415.1-10) have a 6" flue outlet (152 mm). If your exhaust system does not have a 6" diameter, a solution is to insert a stainless liner with a 6" diameter inside the exhaust system.

How do I reduce the amount of charcoal my heater produces?

Appliances that are EPA or CSAB415.1 certified tend to create larger coal beds due to their higher efficiency. This can be controlled by the way you burn your appliance. After an overnight burn, you may have a more significant coal bed. Simply rake the coal bed forward and add a smaller piece of wood on top. Burn the appliance on a higher setting (air control fully open). This will pull more primary air into the firebox and will increase draft. The coal bed will burn down with the log. You may have to repeat this operation a couple of times before the coals are reduced. You are then ready to load your appliance with a larger fuel load.

Tech support

Do I need an EPA certified or CSAB415.1-10 certified heater?

You first have to identify what your needs are. If you are looking for ambiance, a temporary heat source in a cottage or a camp, or a simple back-up heat source in case of power failure, you do not necessarily need to invest more money in order to buy an EPA or CSAB415.1-10 certified wood heater. However, if your goal is to heat on a regular basis, the extra dollars will prove to be a good investment. Furthermore, it must be noted that certified heaters release up to 90% less particles into the atmosphere, which makes wood a renewable and clean source of heat. As a result, if the style and size of the heater you are looking for is available in a certified version, it is highly recommended that you invest in this advanced combustion technology. You will help the environment and reduce your wood consumption by up to 30%.

NOTE: If you live in the United Sates, British Columbia, Ontario, Quebec, Nova Scotia, New Brunswick or Newfoundland, EPA certified wood heaters are mandatory. Exceptions apply for certain categories of products, such as decorative fireplaces. Certain municipalities may also have by-laws that require the installation of an EPA or CSAB415.1-10 wood heater, even though the province does not have an official regulation on wood heating. It must also be noted that in Canada, the CSAB415.1-10 Standard is equivalent to the EPA Standard. A wood heater that meets this Standard will generally comply with the regulation in place.


Why is the efficiency as per the EPA’s test data smaller than the publicized optimum efficiency?

EPA refers to the CSAB415.1-10 standard for the calculation of the appliance’s efficiency. The efficiency reported as per EPA’s directives consists of an average between four different burn rates, ranging from the lowest burn rate (air intake completely closed) to the highest burn rate (air intake completely open). The optimum efficiency that we publicize is the efficiency obtained according to the same test data, but for the low burn rate only. This efficiency is more realistic for a majority of users whose heating needs require that the unit be used to maximize burn times.

Why is the BTU according to EPA test data smaller than the one advertised?

 

You will notice a difference between the BTU output as per the EPA’s test data and what is advertised on our web site and/or product literature. The maximum BTU output we advertise is what will be obtained with a full load of seasoned cordwood inserted inside the firebox. The EPA output, on the other hand, is what has been obtained during emissions testing. The EPA test procedure requires that a special type of wood is used and positioned inside the firebox in a manner that does not represent the way the firebox volume would normally be utilized using seasoned cordwood. The EPA test load is typically much smaller. Hence, the BTU as per the EPA’s test data is reduced. The BTU output that should be considered by a normal user is the one we advertise for seasoned cordwood.

 

Can I install an EPA or CSAB415.1-10 certified heater on an 8-inch chimney?

EPA or CSAB415.1-10 certified heaters function best on a 6-inch chimney (interior diameter). The problem with an 8-inch chimney is that the appliance may struggle to heat-up the air volume contained inside the chimney. A hot chimney is required to create enough draft. Poor draft will inevitably lead to poor combustion, which will cause smoke roll backs, a dirty glass, lack of heat, and a large quantity of unburned fuel inside the firebox. It is therefore highly recommended installing a 6-inch liner inside the 8-inch chimney. This liner may be rigid or flexible.

Reviews

greg tracy - 2016-03-12   

Been burning wood for 35 years an no other heat score . This tundra has saved so much work a real class act .

kathy lee - 2016-03-02   

hi folks it is -25c march 2 2016.so far I have burnt 2 bush cords of wood. I would recommended this furnace to my friends. my wood I burn is dead oak & maple

Paul Rogers - 2016-02-27   

Fantastic product, have had two previous wood furnaces ( I called them wood incinerators) from other manufacturers I believe from1 was from Newmack and the other from Hunter and the Drolet performs like a free standing steel plate wood-stove, whacks out heat when you need it.. I love having the window so that I can see how the fires coming along. Well seasoned, dry wood is definitely essential, mine is not fully seasoned so I frequently clean out the heat ex-changer tubes. Heat out put decrease which immediately tells me they need cleaning. I love the ash drawer and clean out bung in the fire box how ever I'm not impressed with the wing nuts on the ash drawer, the welding securing bolts drag on the hole sin the ash drawer front panel when sliding it out. I feel eventually the bolts will strip over time, a cam locking system would be nicer. I furnace remains cool to the touch on just about the whole exterior casing. Square or rectangular outlet ports for ducting would be better in my install anyway. I have rectangular 8" x 10" duct hooked up to the 8" round ports.

Willie anaka - 2016-02-15   

A great furnace, heats the garage and house, since purchased had no need to turn on the electric boiler, refereed it to a friend and he is also pleased..... (Note just last week found a crack beside the hinges on the front of the furnace, waiting to see how the warranty works out.)

Roger Cossette - 2016-02-11   

Très satisfait du rendement de chaleur avec moins de bois que mon ancien poêle. Il reste peu de cendres.

Scott Dickman - 2016-01-25   

Was impressed with attention to detail,nice paint, galvanized fan box and quality fan.Talked to a Drolet tech.before purchase,he was very informative and gave me plenty of his time to explain the function of the drafting system.The burn in the firebox is impressive,seems like a great design. Feel like I made the right choice.

Rupert Hare - 2015-12-16   

We installed the Tundra to replace a older wood stove that was our primary source of heat. Installation of furnace and duct work was quite straight forward for any one who is handy and did not require any specialized tools. The furnace is very easy to operate and it's performance has greatly exceeded our expectations providing significantly more heat very quickly while burning less wood. Very satisfied and would recommend the stove.

hohn smith - 2015-12-12   

very happy with the performance of the furnace, the quality of the product and the cost compared to other manufacturers products with similar performance.highly recommended.

Kit Kosina - 2015-10-25   

My new Tundra works as advertised. Efficient, excellent heat, long burn times. So far I am totally satisfied with my purchase from Drolet. Bought it to heat my 2000 sq. ft. house. Can't wait till middle of winter to give it the finale test. Although I'm sure we will be nice abd toasty!!!

Charlie Shier - 2015-03-17   

Awesome product hands down

Hjalmer Lamminen - 2015-02-25   

The furnace was easy to install and started right up. First night was below zero degrees F. It is taking less than half of the wood that the old DAKA brand wood stove did. No odor of smoke backing up into the house. So far it is a great furnace.

Bob Robblee - 2015-02-10   

I replaced an 30 year old wood furnace with the Tundra. It is a well designed and built device and is doing an excellent job of warming my home. And, like other wood fired stoves I have used over the past 40 years, it keeps itself warm 5 hours after being stuffed full of good wood if not refilled at that time. Kudos to you folks for building what should have been done 35 years ago and works just like the older, standard furnaces. Regards, Bob Robblee

kathy lord - 2014-03-08   

I would give this furnace a B+ it would be an awsome furnace for a new home, looks are nice ,glass door is nice, quiet operation and very easy to hook up.

Roland Eddy - 2014-01-20   

Very easy to lite, easy to hook-up to excisting duck work, good burning and good heat, love the glass door.

normand petit - 2014-01-06   

i love the heat this furnace generates every thing is so easy with this furnace putting the wood in starting it.its a master piece

Gary Prosser - 2013-12-07   

Very pleased with the look, efficiently and heat output. All my friends and neighbours are very impressed and will be purchasing the same very soon. Lights very easily, the thermostat controls the burn rate and the heat combined with efficiency is very impressive!!

Anne Stupavsky - 2013-11-06   