Why is the BTU according to EPA test data smaller than the one advertised?
You will notice a difference between the BTU output as per the EPA’s test data and what is advertised on our web site. The maximum BTU output we advertise is what will be obtained with a full load of seasoned cordwood inserted inside the firebox. The EPA output, on the other hand, is what has been obtained during emissions testing. The EPA test procedure requires that a special type of wood is used and positioned inside the firebox in a manner that does not represent the way the firebox volume would normally be utilized using seasoned cordwood. The EPA test load is typically much smaller. Hence, the BTU as per the EPA’s test data is reduced. The BTU output that should be considered by a normal user is the one we advertise for seasoned cordwood.
How do I know if an appliance is EPA certified?
The EPA 2020 certification of an appliance can be checked in three places:
On the certification plate
Locate towards the bottom of the plate, just above the safety notices, the section that indicates ''U.S. ENVIRONMENTAL PROTECTION AGENCY. Certified to comply with 2020 particulate emission standards with cordwood''.
In the manual
In the installation and user manual, go to the performances table in the “General information” section and locate the line “Average particulate emission rate” – it will show EPA if the appliance is EPA certified.
On the website
Go to the product page in which you are interested. In the ''Specifications'' section, locate the lines ''High-efficiency certified appliance'' and ''US Standard (emissions)'' - these will respectively show ''Yes, EPA 2020 Approved'' and ''EPA'' if the appliance is EPA certified.
In the event of a discrepancy between the information displayed on the plate and the other references, the values on the certification plate always have priority.
How do I reduce the amount of charcoal my heater produces?
Appliances that are EPA or CSAB415.1 certified tend to create larger coal beds due to their higher efficiency. This can be controlled by the way you burn your appliance. After an overnight burn, you may have a more significant coal bed. Simply rake the coal bed forward and add a smaller piece of wood on top. Burn the appliance on a higher setting (air control fully open). This will pull more primary air into the firebox and will increase draft. The coal bed will burn down with the log. You may have to repeat this operation a couple of times before the coals are reduced. You are then ready to load your appliance with a larger fuel load.
Why is the efficiency as per the EPA’s test data smaller than the publicized optimum efficiency?
EPA refers to the CSAB415.1-10 standard for the calculation of the appliance’s efficiency. The efficiency reported as per EPA’s directives consists of an average between four different burn rates, ranging from the lowest burn rate (air intake completely closed) to the highest burn rate (air intake completely open). The optimum efficiency that we publicize is the efficiency obtained according to the same test data, but for the low burn rate only. This efficiency is more realistic for a majority of users whose heating needs require that the unit be used to maximize burn times.
Why does the fire go out when I close the loading door?
Possible causes and solutions:
1. The moisture content of your wood is too high.
Solution: Make sure you use good, seasoned cord wood. The wood you burn plays an important role in the overall performance of your heater. Your wood should have been properly dried for approximately one year. Storage is also key. Wood that has been cut for one, two or even more years will not necessarily be dry if it has been stored in poor conditions. Under extreme conditions, it may have rotten instead of drying. Smaller pieces of wood will dry faster. The wood should be stored in a place where the grass is not too long, and where the wind will be able to circulate between the logs. A 12-inch gap should be kept between the cords. The wood should be placed in the sunniest area and should be protected from the rain and snow on top, but not on the sides. Use a moisture reader to measure the moisture content of your wood. Ideally, it should be below 25%.
2. The air control mechanism is not open enough.
Solution: Adjust the air control mechanism in order to keep the flue temperature within the comfort zone (between 250 °F and 475 °F) on your chimney thermometer. The air control mechanism must always be closed gradually. You need to obtain a good bed of red embers and the logs must be completely lit up before you close the air control completely. This can easily take up to one hour.
3. The logs that you are using are too big.
Solution: Use smaller pieces of wood and place them to allow proper air circulation between the logs. The same weight of wood cut in many small pieces will produce more heat than fewer, larger logs. Only add big logs when you have a good bed of red embers. Logs with a diameter exceeding 6 inches should always be split. Avoid stacking logs to the top of the firebox.
4. The chimney draft is too weak.
Solution #1: In many cases, a weak draft is simply due to insufficient heat in the exhaust system. Build a small, intense fire, and leave the door ajar (never leave the heater unattended). Before inserting larger logs, use dry kindling to obtain a good bed of red embers. Gradually increase the size of the logs. Close the unit’s door when you reach a flue temperature of approximately 475 °F on the chimney thermometer. Leave the air intake fully open for approximately 15 minutes. Then, gradually close the air intake control. Note that there is no danger in letting the temperature inside the flue reach approximately 700 °F during the start-up. This is even favorable in order to properly start your heater. You must, however, avoid maintaining excessive temperatures (above the comfort zone on your thermometer) during a long period of time. Your chimney thermometer should be positioned on the exhaust pipe, approximately 18 inches above the unit.
Solution #2: Your heater may not have all the oxygen it needs to allow for a sufficient draft. You first need to ensure that the room where the heater is located is sufficiently large and well ventilated. Open the nearest window by approximately 2 inches. If you notice a significant improvement, it is a sign that the unit needs more oxygen. The room may be too insulated or too small. Without an additional source of oxygen, the draft will remain weak and cause the glass stay dirty.
Solution #3: The chimney may be too short. In order to obtain a sufficient draft, your chimney must have a minimum height. Twelve feet (from the heater to the chimney cap outside the house) is a minimum. A height of 15 feet or higher is ideal.
Solution #4: Your exhaust system may be too tortuous or may lack a sufficiently steep slope. Ideally, your exhaust system should not have more than one 90° elbow. Furthermore, all horizontal sections should be as short as possible and have a minimum slope of 1/4" per foot.
Solution #5: Your exhaust system may be oversized. When your chimney is oversized, the volume of air that needs to be warmed-up is larger. It is therefore difficult to reach temperatures that will allow for a sufficient draft. Most advanced combustion systems (those certified to EPA/CSAB415.1-10) have a 6" flue outlet (152 mm). If your exhaust system does not have a 6" diameter, a solution is to insert a stainless liner with a 6" diameter inside the exhaust system.
Why is there smoke when I use my heater?
Possible causes and solutions:
1. Your heater is new and thin smoke is coming out of the unit’s surface.
Solution: This is normal when your heater is new and has never been used. The paint needs to be "cured". You need to heat your appliance two or three of times before the curing process is completed. Simply open a window in the room where the unit is located. The amount of smoke produced by the curing process should be very limited. If the area is well ventilated, there is no health hazard.
2. The chimney in under negative pressure.
Solution#1: The chimney may simply be too cold. Light-up a small quantity of newspaper in the appliance, as close as possible to the flue outlet. Leave the door slightly ajar. This small fire will slowly heat-up the chimney, until it is hot enough to create a normal draft inside the exhaust system. If needed, slowly increase the quantity of newspaper. When you realize that smoke is being evacuated normally through the exhaust system, you can build a normal fire. If your chimney runs along the outside wall of your house, it is possible to cover it up in order to protect it from the wind and the cold. A covered chimney will heat-up faster.
Solution #2: Negative pressure may be caused by air-moving devices, such as a range hood, a bathroom fan, or an air exchanger. Check if smoking problems occur when those devices are working. If it is the case, make sure you turn them off when you use your heater. Otherwise, you need to make sure that the air leaving the room is replaced by air from outside the house. For instance, you can open a window slightly (by one or two inches). Ideally, the source of fresh air should be located as close as possible to the heater. A good, permanent solution is the installation of a fresh air intake. It should be located as close as possible to the unit. The appliance will draw its combustion air from this nearby supply. It will prevent the house from falling into negative pressure. Some units are designed to receive an adapter on which the fresh air supply pipe can be directly connected. This way, the appliance will always draw its combustion air from outside the house.
Solution #3: Negative pressure may be caused by wind, due to the interference from a nearby structure. In order to eliminate such interference, the extremity of your chimney should be at least two feet higher than any structure located within a ten-foot radius.
Do I need to install a fresh air intake on my wood heater?
A fresh air intake is not mandatory for your wood heater, unless the unit is installed in a mobile home or if the local building code or the manufacturer requires it. If the heater is installed in an open room, in a house that is more or less air-tight, combustion air will normally be easily replaced. In this case, the installation of a fresh air intake is not required. It must, however, be noted that a fresh air intake, even if it is not mandatory, will always provide the advantage of better balancing the house with regards to combustion air. If the house has a powerful mechanical exhaust system that may be used while the heater is burning (ex: range hood), a fresh-air intake will be required.
Do I need a floor protection under and around my heater?
Yes, floor protection is required for any wood appliance unless the unit already sits on a non-combustible surface. You have many choices, such as stone, brick, cement board, or tile. You need to consult your owner's manual in order to know the dimensions of the floor protection specific to your model. In Canada, the floor protection must extend in front of the unit by at least 18 inches and by at least 8 inches on each side. In the USA, the floor protection must extend at least 8 inches on each side of the appliance (measured from the door opening) and at least 16 inches in front of the door opening.
What burn time will I get from my wood heater?
The combustion time for an EPA or CSAB415.1-10 certified, non-catalytic wood appliance depends on many factors, the most important being the size of its firebox. Heaters with a 2.0 cubic foot firebox or more will normally have longer burn-times. From 6 to 8 hours is about the burn time you will get. Some companies will advertise longer burn times, but be careful, this calculation is made from the time you light the fire to the time there is absolutely no combustible left into the firebox. No matter what the appliance model is, the maximum BTU output will be obtained over approximately 33% of the total burn cycle. This represents 2 to 3 hours for a medium-size stove. So realistically, you will have to reload the unit every 3 or 4 hours in order to get the maximum heat out of your appliance when you are home. If you don’t reload the heater and let it burn the remaining fuel, your output will slowly decrease until there is no useful heat left to produce (we call this the “tail end” of the combustion cycle). This “tail end” will provide heat for another 4 to 5 hours. So if you are looking for a 6 to 8-hour burn time, make sure you choose an EPA or CSAB415.1-10 certified wood heater with a BTU output (using cordwood) of 60,000 BTU or more. Appliances with that kind of output all have fairly large fireboxes. If you are going to rely mostly on wood for heating and your house has more than 2,000 square feet, do not hesitate to choose one of our larger units (>85,000 BTU). Those appliances will have a burn time of approximately 8 to 10 hours.
Why does the glass get sooty?
Possible causes and solutions:
1. The moisture content of your wood is too high.
Solution: Make sure you use good, seasoned cord wood. The wood you burn plays an important role in the overall performance of your heater. Your wood should have been properly dried for approximately one year. Storage is also key. Wood that has been cut for one, two or even more years, will not necessarily be dry if it has been stored in poor conditions. Under extreme conditions, it may have rotten instead of drying. Smaller pieces of wood will dry faster. The wood should be stored in a place where the grass is not too long, and where the wind will be able to circulate between the logs. A 12-inch gap should be kept between the cords. The wood should be placed in the sunniest area and should be protected from the rain and snow on top, but not on the sides. Use a moisture reader to measure the moisture content of your wood. Ideally, it should be below 25%.
2. The logs are positioned too close to the glass and are obstructing the air flow that is necessary to keep the glass clean.
Solution: Make sure to keep a minimum gap of 2 inches between the logs and the glass.
3. The chimney draft is too weak.
Solution #1: In many cases, a weak draft is simply due to insufficient heat in the exhaust system. Build a small, intense fire, and leave the door ajar (never leave the heater unattended). Before inserting larger logs, use dry kindling to obtain a good bed of red embers. Gradually increase the size of the logs. Close the unit’s door when you reach a flue temperature of approximately 475 °F on the chimney thermometer. Leave the air intake fully open for approximately 15 minutes. Then, gradually close the air intake control. Note that there is no danger in letting the temperature inside the flue reach approximately 700 °F during the start-up. This is even favorable in order to properly start your heater. You must, however, avoid maintaining excessive temperatures (above the comfort zone on your thermometer) during a long period of time. Your chimney thermometer should be positioned on the exhaust pipe, approximately 18 inches above the unit.
Solution #2: Your heater may not have all the oxygen it needs to allow for a sufficient draft. You first need to insure that the room where the heater is located is sufficiently large and well ventilated. Open the nearest window by approximately 2 inches. If you notice a significant improvement, it is a sign that the unit needs more oxygen. The room may be too insulated or too small. Without an additional source of oxygen, the draft will remain weak and cause the glass stay dirty.
Solution #3: The chimney may be too short. In order to obtain a sufficient draft, your chimney must have a minimum height. Twelve feet (from the heater to the chimney cap outside the house) is a minimum. A height of 15 feet or higher is ideal.
Solution #4: Your exhaust system may be too tortuous or may lack a sufficiently steep slope. Ideally, your exhaust system should not have more than one 90° elbow. Furthermore, all horizontal sections should be as short as possible and have a minimum slope of ¼" per foot.
Solution #5: Your exhaust system may be oversized. When your chimney is oversized, the volume of air that needs to be warmed-up is larger. It is therefore difficult to reach temperatures that will allow for a sufficient draft. Most advanced combustion systems (those certified to EPA/CSAB415.1-10) have a 6" flue outlet (152 mm). If your exhaust system does not have a 6" diameter, a solution is to insert a stainless liner with a 6" diameter inside the exhaust system.